BENEFITS OF RIF® BUSHINGS OVER OTHER BUSHING TECHNOLOGIES

Feature

RIF®

Dry type, paperless

(Resin Impregnated Fibreglass)

RIP

Dry type, paper

(Resin Impregnated Paper)

OIP

Oil-filled. paper

(Oil impregnated paper)

Maintenance

Maintenance-free

Tan δ and C1 need to be checked regularly.

Tan δ and C1 need to be checked regularly.

DGA testing of the bushing oil should be done on older bushings.

Leak mitigation.

Explosion-resistant

Yes (This has been validated with an internal arcing fault test. Arc fault current = 31.5 kA; arc duration = 150 ms)

No

No

Thermal temperature rating of insulation

130°C

A higher thermal margin.

120°C

105°C

Optional built-in insulation condition monitoring

The test tap can also be supplied with an LED sensor that provides visual indication of the real-time condition of the bushing insulation. The built-in circuitry detects any change to the C1 capacitance. LED status lite - GREEN for GOOD and RED for a possible deteriorating condition.

Not provided

Not provided

Cost to produce custom design “like for like” replacement bushings

Low

No re-tooling required for custom designs.

High

Expensive re-tooling required for custom designs. Cost and lead time significantly impacted.

High

Expensive re-tooling required for custom designs. Cost and lead time significantly impacted.

Cost of ownership

Low.

Lower production costs than RIP.

Maintenance-free.

High reliability.

Explosion-resistant.

Medium.

High production costs. Regular off-line Doble testing required.

Expensive long-term storage requirements.

Higher.

Lower production costs than RIP and RIF®.

Regular off-line Doble testing required.

DGA testing of bushing oil recommended for older bushings.

Leak mitigation.

Can fail catastrophically jeopardizing the transformer, surrounding substation equipment and the safety of on-site personnel

Long term storage

No special requirements. Can be stored horizontally in their shipping crate.

This technology uses creped insulating paper dried under temperature and impregnated under vacuum with epoxy resin. Therefore, RIP is sensitive to humidity ingress. Long term storage requires the oil end to be fitted with specially designed metallic covers filled with dry transformer oil.

Must be stored in an upright position to avoid creating air bubbles.

Filed Under: Products

Company
- About RHM
- Why RHM
- Opportunities
- Contact

Technical Resources
- Product Specification Sheets
- Publications
- Downloads
- Quality & Supply Chain
- ISO 9001

Resources
- Blog
- Privacy Policy

©2026 RHM International, LLC. All Rights Reserved. Developed by BBDS Design