RHM International, LLC

Innovative High Reliability High Voltage Equipment for the Power Grid

Menu
  • Home
  • Products
    • RHM International current transformer typesCurrent Transformers
      • LRGBJ Series – up to 550kV
      • LRGBJ-ZH Cascade Series – above 220kV
      • LRGBJ – ZHD Series for High Currents
      • GDGL Optical/Electronic Series
      • Shunt Capacitor Bank Applications
    • Dry Insulation high voltage transformer bushings by RHM InternationalTransformer Bushings
      • RIF® – FGRBW Tough Series
      • Cascade RIF® for EHV Applications
      • Built-In Insulation Monitoring
    • RHM International high voltage wall bushingsWall Bushings – Special Bushings
      • STB Wall Bushings Specifications
      • STB-L Series: Wall Bushing with CT
      • Special Bushings — Custom Designs
    • cable termination by RHM InternationalHV DRY TYPE OUTDOOR CABLE TERMINATOR
      • Cable Terminator
    • Electronic Combined Voltage and Current Transformer REVCT35-1000 Series 35 kV – 1000 kV by RHM InternationalIEC 61850 Ready and NCITs
      • BIIT™ HV MEASUREMENT BUSHING
      • Optical/Electronic Current Transformer
      • Electronic Combined VT and CT
      • Smart Monitoring
    • Close
  • Why Us
    • Company Advantages
      • Shorter Lead Time
      • Custom Designs
      • Testing Capabilities
      • Quality & Supply Chain
      • ISO 9001
    • Product Benefits
      • Outstanding Performance
      • No Maintenance
      • No Explosions
      • Easy Storage
      • Environmentally Friendly
      • Longer Life & Higher ROI
      • Sustained Higher Performance
      • Proven Track Record
    • Expertise & Assistance
    • Close
  • Technology
    • 1Our Technologies
      • HV DryShield® for CT’s & Wall Bushings
      • RIF® Insulation for Transformer Bushings & Cable Terminators
    • smart-monitoringSmart Monitoring
      • Built-in Condition Monitoring
      • Bushing based Transformer PD Monitoring
    • The-Dry-Type-RIF-Bushing_The-New-Technology-in-HV-Bushings-1Publications
      • BIIT Bushings: Intelligent HV bushings w/ integrated low power voltage and current transformers
      • HV DryShield® – A dry type HV insulation system for extreme environments
      • RIF ® bushings The paperless, dry-type bushing technology
      • The Dry Type RIF ® Bushing: New Technology in HV Bushings
      • Advances in Bushings Technology – Integrated Monitoring Systems
    • 3Product Specification Sheets
      • Current Transformers
      • Wall Bushings
      • IEEE Bushings
      • IEC Bushings
      • Cable Terminals
    • Installation & Testing
    • Close
  • Your Specs
  • HV Testing Services
  • About Us
  • Blog
  • Opportunities
  • Contact Us

First 600 kV AC Dry Type Current Transformers Put Into Service in North America

600 kV Dry Type Transformers Energized in the MMTP Transmission Project

On June 1, 2020 the first ever 600 kV AC dry type current transformers installed in North America were energized and put into service in the Province of Manitoba, Canada. Manitoba Hydro, the publicly-owned electric and natural gas utility for the Province of Manitoba purchased six (6) RHM International 600 kV dry type LRGBJ-ZH-600 current transformers for the Manitoba – Minnesota Transmission Project (MMTP) which involved the building of a 500 kV AC transmission line from the City of Winnipeg area to the United States of America border, then continued as the Great Northern Transmission Line to the Iron Range 500 kV AC Substation near Grand Rapids, Minnesota, USA. The 600 kV dry type current transformers purchased for the new MMTP 500 kV AC line’s protection and metering requirements were installed at Manitoba Hydro’s Dorsey and Riel Converter Stations.

MMTP Transmission Line Route

MMTP Transmission Line Route (Source: Electrical Industry Newsweek)


Technical Specifications for the 600 kV AC Dry Type LRGBJ-ZH-600 Current Transformers Supplied for the Manitoba-Minnesota Transmission Project (MMTP)

600 kV AC Dry Type LRGBJ-ZH-600 CTs at the Dorsey Converter Station (

600 kV AC Dry Type LRGBJ-ZH-600 CTs at the Dorsey Converter Station (Courtesy: Manitoba Hydro)

600 kV AC Dry Type LRGBJ-ZH-600 CTs at the Riel Converter Station (Courtesy: Manitoba Hydro)

600 kV AC Dry Type LRGBJ-ZH-600 CTs at the Riel Converter Station (Courtesy: Manitoba Hydro)

MMTP Transmission Line Facilitates Manitoba Hydro Export Sales to US

This was a very important project for the utility as it allowed Manitoba Hydro to fulfill their export sales agreements while providing increased access to new markets in the USA for future sales. Export sales are an important revenue source for the utility as it allows Manitoba Hydro to have domestic electricity rates among the most competitive in North America.

LRGBJ-ZH-600 Dry Type Current Transformer

The LRGBJ-ZH-600 dry type current transformer is a cascade double decker two stage design, composed of two CTs (an upper CT unit and lower CT unit) each with a rated voltage of about 300 kV. The pedestal of the upper CT unit is bolted to the top of the lower CT unit. In this configuration the secondary of the upper CT unit is electrically connected in series with the primary winding of the lower CT unit. The cascade design also allows the LRGBJ-ZH-600 current transformer to be shipped in two separate CT pieces which makes it easier to transport and install at site.

Dry Type CTs Have Better Safety Profile

The RHM International dry type CT design has eliminated the safety risks and maintenance issues associated with the use of oil, kraft paper, pressurized insulating gas, and the porcelain insulator bushing. The RHM International dry type CT has been designed for a minimum life expectancy of forty (40) years, with additional decades of trouble-free operation expected.

“We should be excited about the advent of new technologies that support the environment and promote safety and reliability.”
-- Derek Barker, P.Eng., Apparatus Quality Control, Manitoba Hydro

Technical Specifications for the 600 kV AC Dry Type LRGBJ-ZH-600 Current Transformers Supplied for the Manitoba-Minnesota Transmission Project (MMTP)

Nominal system voltage

500 kVrms

Maximum continuous operating voltage

600 kVrms

Rated primary current of upper CT unit

2000 x 4000 A

Rated primary current of lower CT unit

16 A

Primary current rating factor

1.0

Rated secondary current of upper CT unit

16 A

Rated secondary current of lower CT unit

5-5-5-5 A

Secondary current rating factor

1.0

Accuracy class and burden (on maximum taps)

10L800 and 0.3B1.8 at 0.9 PF

Protective class

PX. Ratings: Vk ≥ 800V, Iexc ≤ 10A

Number of primary sections

2

Number of cores

4

Rated power frequency 1 minute withstand

860 kVrms

Rated lightning full wave impulse withstand

1800 kVpeak

Rated lightning chopped wave withstand

Rated switching impulse withstand

2070 kVpeak

1300 kVpeak

1 sec thermal short circuit fault rating

63 kArms

Mechanical dynamic short circuit rating

150 kApeak

Ambient temperature operating range

-50°C to +40°C

Creepage distance (heavy pollution, 25mm/kV)

15000 mm

Seismic level

High

Capacitance tap

Full 100%

Internal arc protection

Class II

Design life expectancy (minimum)

40 years

Measurement Canada approval no.

AE-2354

REFERENCES
1) Manitoba–Minnesota Transmission Project. MMTP Project Description

2) Great Northern Transmission Line.