RHM International, LLC

Innovative High Reliability High Voltage Equipment for the Power Grid

Menu
  • Home
  • Products
    • RHM International current transformer typesCurrent Transformers
      • LRGBJ Series – up to 550kV
      • LRGBJ-ZH Cascade Series – above 220kV
      • LRGBJ – ZHD Series for High Currents
      • GDGL Optical/Electronic Series
      • Shunt Capacitor Bank Applications
    • Dry Insulation high voltage transformer bushings by RHM InternationalTransformer Bushings
      • RIF® – FGRBW Tough Series
      • Cascade RIF® for EHV Applications
      • Built-In Insulation Monitoring
    • RHM International high voltage wall bushingsWall Bushings – Special Bushings
      • STB Wall Bushings Specifications
      • STB-L Series: Wall Bushing with CT
      • Special Bushings — Custom Designs
    • cable termination by RHM InternationalHV DRY TYPE OUTDOOR CABLE TERMINATOR
      • Cable Terminator
    • Electronic Combined Voltage and Current Transformer REVCT35-1000 Series 35 kV – 1000 kV by RHM InternationalIEC 61850 Ready and NCITs
      • BIIT™ HV MEASUREMENT BUSHING
      • Optical/Electronic Current Transformer
      • Electronic Combined VT and CT
      • Smart Monitoring
    • Close
  • Why Us
    • Company Advantages
      • Shorter Lead Time
      • Custom Designs
      • Testing Capabilities
      • Quality & Supply Chain
      • ISO 9001
    • Product Benefits
      • Outstanding Performance
      • No Maintenance
      • No Explosions
      • Easy Storage
      • Environmentally Friendly
      • Longer Life & Higher ROI
      • Sustained Higher Performance
      • Proven Track Record
    • Expertise & Assistance
    • Close
  • Technology
    • 1Our Technologies
      • HV DryShield® for CT’s & Wall Bushings
      • RIF® Insulation for Transformer Bushings & Cable Terminators
    • smart-monitoringSmart Monitoring
      • Built-in Condition Monitoring
      • Bushing based Transformer PD Monitoring
    • The-Dry-Type-RIF-Bushing_The-New-Technology-in-HV-Bushings-1Publications
      • BIIT Bushings: Intelligent HV bushings w/ integrated low power voltage and current transformers
      • HV DryShield® – A dry type HV insulation system for extreme environments
      • RIF ® bushings The paperless, dry-type bushing technology
      • The Dry Type RIF ® Bushing: New Technology in HV Bushings
      • Advances in Bushings Technology – Integrated Monitoring Systems
    • 3Product Specification Sheets
      • Current Transformers
      • Wall Bushings
      • IEEE Bushings
      • IEC Bushings
      • Cable Terminals
    • Installation & Testing
    • Close
  • Your Specs
  • HV Testing Services
  • About Us
  • Blog
  • Opportunities
  • Contact Us

Choosing the Right Bushing Technology to Mitigate the Consequences of a Bushing Turret Rupture

In a recent CIGRE publication the loss of a single phase GSU transformer due to an HV bushing turret rupture was discussed. In this case an OIL/SF6 RIP bushing failed catastrophically inside its turret which led to the rupture of the turret and the loss of a multi-million-dollar transformer from the resultant fire.

Transformer manufacturers have been working on ways to improve the mechanical resilience of transformer tanks to better withstand the overpressure generated by an internal arcing fault. IEEE also offers a guide (C57.156-2016) describing measures that transformer manufacturers can take to help mitigate tank rupture. However, the article in the CIGRE publication was quick to highlight that more work is required to improve the mechanical resilience of bushing turrets as oil-filled turrets may not be able to withstand a catastrophic failure of the oil end part of the bushing. The article goes on to describe a retrofit solution for HV bushing turrets using PRD protection. We would like to suggest an alternate solution to mitigate this risk by installing bushings that can maintain their oil end structural integrity in the event of an arcing fault. This would have protected the transformer from a catastrophic turret rupture and the subsequent fire that destroyed the transformer. In an earlier blog article, we described an internal arc fault test that was conducted on an RHM International 230 kV dry type RIF® bushing which passed the stated test criteria of “no ignition of the arc or destruction of the oil side of the bushing under the supporting plate”.

Air End of Transformer Bushing

Air End

Oil End after test

Oil End